DSC 1. 83. 2 — Super Security Tech+ Zone wiring details. All hardwired zones can be either normally closed (no resistors), single EOL (with a 5. K Ohm resistor), or double end of line (where you have two 5. K Ohm resistors, one across the alarm contact and one in series with the tamper). To set the zone EOL resistor value, go to location 0. ON = Normally closed zones (use no resistor, just closed loops)1 - OFF = Use resistor value set in option 2 below. Contact Us: Honeywell Security and Fire 2 Corporate Center Drive, Suite 100 Melville, New York 11747. Sales 1- 800-323-4576. View and Download Ademco Vista-32FB installation and setup manual online. Commercial Fire and Burglary Partitioned Security System with Scheduling. Vista-32FB. To programme a Vista 32FB/128FB, you need to press * or # and then a location number. Pressing # then a location number will allow you to view that location, this can. VISTA=20 2-PARTITIONED SECURITY SYSTEM PROGRAMMING FORM Principal changes in this issue are indicated by margin lines. VISTA-20PRV3 4/96 (See Instructions N7526V3). ![]()
![]() ON = Double end of line (use one 5. Ohm Resistor)2 - OFF = Single end of line (use 2x 5. Ohm Resistors)Fire zones must be wired differently. Regardless of how location 0. K Ohm resistor wired across the normally open terminals so the fire alarm will short the resistor out when it is activated. Use zone type 0. 8 for hardwired smoke detectors and 8. Programme a hardwired zone. ![]() To programme a hardwired zone, there are a couple of things that need to be setup. You need a zone type LOCATION 0. The zone must be in a partition LOCATION 2. Zone attributes can be changed LOCATION 1. ![]() ![]() ![]() Zones need a 2- digit zone type assigned for them to work. As you programme each 2- digit zone type, it will jump to the next zone. When you finish all 1. ![]() If you are only programming the 6 on board zones, just press # when you have programmed the last zone you wish. To skip a zone press the arrow key twice. The zone type will determine how the zone will work. LOCATION 0. 02 has slots for zones 1. View all zone types. Assign the zone to a partition, by default only zones 1- 8 are assigned to partition 1. Location 2. 02 toggles zones 1- 8 into partition 1, locations 2. Zone attributes, can be changed to alter how the zone works. Each zone type has set attributes, but you can change them after you assign the zone type.+ Programme a wireless zone. To set up a wireless zone, there are a few key things that need to be programmed. You can programme any of the first 1. You need a zone type LOCATION 0. You must tell the panel the zone is wireless LOCATION 1. The zone must be in a partition LOCATION 2. You must programme in the ESN (electronic serial number) LOCATION 8. Zone type is changed in location 0. Once in location 0. When you are at your zone slot, enter the zone type you want to assign the wireless zone. If it's a fire zone, use zone type 8. You cannot use any of these zone types: 0. Press # to leave zone types. Location 0. 02 is for zones 1. ![]() View all zone types. Set zone to wireless in location 1. XX, where XX is the zone number you are using. Use 1. 09 for zone 9; if you were using zone 1. Toggle number 8 on to set the zone to wireless. Assign the zone to a partition, by default only zones 1- 8 are assigned to partition 1. Location 2. 02 toggles zones 1- 8 into partition 1. Location 2. 02- 2. Enroll the wireless zone by entering location 8. Once in location 8. ESN (electronic serial number) on the device. Press # to leave location 8. Wireless module placement, enter location 9. Enter the 2- digit zone number. It is now awaiting your test. Make sure you take the device to where it will be installed and trip the sensor. The keypad will display 1 for good, 2 for ok, or 3 for bad. If you aren't using a tamper switch where the expander is installed then loop a wire between the tamper terminal and any zone common terminal. Perform a module reset from inside programming mode. Enter LOCATION 9. Delete a zone. Deleting a zone is a simple one step process. Changing the zone type to 0. LOCATION 0. 01- 0. Once in location 0. Once at the zone you wish to delete, just enter 0. Location 0. 02 starts at zone 1. Keypad zones. Each keypad has a spare terminal that can be used as a keypad zone or output. For a zone, just wire the sensor loop across the P/Z and B terminals. If it's a powered device, you can also power it from the R and B, just make sure you are not drawing too much power. There are 2 things you need to programme to enable the keypad zone: The keypad must be assigned a slot The zone must be assigned to that slot. To assign the keypad slot, enter programming mode from the keypad you are setting up. Enter Location 0. You now need to enter 2- digits, the first digit is the partition the keypad will be assigned to and the second digit is the slot the keypad is in; you can select slots 1- 8. If there is more than one keypad on site, be sure they each have a different slot. Press # to leave keypad programming. To assign a zone to that slot you must first pick a zone not in use (like with the wireless zones, you shouldn't pick zones 1- 8 or you are short changing yourself a zone). From Location 0. 20 you can enter that 2- digit zone number that will be assigned to keypad slot 1. If you didn't pick slot 1, then press the right key > twice to skip to slot 2, and so on, up to slot 8. The zone is now setup as a keypad zone. Be sure to programme it as a hardwired zone, with a zone type and partition.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
September 2017
Categories |